<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-16 00-21-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 46 dBuV ISKELMA
Pilot RDS Phase Difference
6.5 kHz 3.5 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 68 kHz 19038 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,8 dBr 5,72 dBr 6,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 68 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/16 0.20.22 Total samples: 19038 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,2 dBr MIN: 4,8 dBr AVE: 5,72 dBr % above 12,2 dBr: 0,0 Last value: 6,0 dBr (2025/12/16 0.20.21) 00.06 00.08 00.10 00.12 00.14 00.16 00.18 00.20 0 2 4 6 Pm [dBr]